1. Install an Electrical Outlet
WARNING: Risk of electric shock, fire, or personal injury.
This product must be grounded. Connect only to a dedicated
120 VAC, 60 Hz circuit protected by a minimum 15 Amp
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current
Device (RCD).
Do not use an extension cord with the product.
NOTE: Follow local codes when determining the electrical outlet
location.
Route the electrical and install to a 120 V GFCI- or RCD-protected
receptacle. The electrical outlet should be located within 12 (30.5
cm) of the toilet to accommodate the length of the power cord.
Supply Stop
GFCI/RCD-Protected
Receptacle
Kohler Co. 9 1093479-2-A