Install the Electrical Supplies (cont.)
Electrical Rating 240 V, 59 A, 50/60 Hz 240 V, 68 A, 50/60 Hz
Water Supply 3/8 copper line 3/8 copper line
Water Supply Shut-Off Valve 3/8 NPT female 3/8 NPT female
Steam Line 1/2 copper line (1/2 NPT
thread)
1/2 copper line (1/2 NPT
thread)
Pressure Relief Valve (supplied) 3/4 NPT female thread 3/4 NPT female thread
Sizing The Steam Room 894 cu ft (25 cu m) 1000 cu ft (28 cu m)
DANGER: Risk of electrocution. Disconnect the electricity to the working area at the main breaker
panel before performing these installation steps.
Follow all local electrical codes. All electrical work should be done by a qualified electrician.
Review the illustration showing specific Steam Generator Installation Requirements for your Steam
Generators.
Install the appropriate electrical supplies.
Kohler Co. 7 1053777-2-D